User's Manual
Electronic Instrument Installation
Important GE Dresser mounting bracket kit does not include the cable required to
connect the 100G series remote gas module to the Amphenal connector on the
IMC\W2.
GE Dresser Accessories
Description
GE Dresser Part Number
9" A-B male cable 054983-012
9" D-E male cable 054983-010
To attach the ERT module to the IMC\W2 and MC2
1. Insert the 8-32 x 7/16-inch screw (A) into the top of the mounting bracket. Insert the two 8-32 x 3/4-inch
screws (B) into the bottom of the mounting bracket.
2. Insert one 3/32-inch nut on the top 7/16-inch bracket screw (A). Slide the 100G series remote gas module
mounting lug over the top of the bracket screw and nut.
3. Secure the bottom 100G series remote gas module mounting holes over the two 8-32 x 3/4-inch screws
with the remaining two 8-32 nuts.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 54
Proprietary and Confidential