User's Manual
Rotary Meter Installation
To enable enhanced security and for more complete programming information, see the Field Deployment
Manager Endpoint Tools Mobile Application Guide (TDC-0934).
FC200SR FC300 with SRead 900MHz Belt Clip Radio
To program the remote ERT module
• Program the meter drive rate into the 100G series remote gas module using a handheld computer or Belt
Clip Radio and laptop computer.
• For all programming and Check Endpoint operations using a handheld computer, hold the handheld as
close to vertical as possible. For best success, keep the handheld within six feet of the target ERT module.
• Verify you have the correct programming mode (fixed network mode, mobile high power mode,
mobile/handheld mode, or hard-to-read mobile/handheld mode) for your application.
Programming parameters are based on the configuration file loaded into the programming device. During
programming, the 100G series remote gas module is set to the nearest 100 cubic feet; the last two digits (tens
and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read
to the nearest cubic foot.
• Read or Check the 100G series remote gas module using the handheld computer or Belt Clip Radio.
• If the read result is higher than the number programmed in step 1, the 100G series remote gas module
is counting correctly.
• If the read result is not higher than the number programmed in step 1, replace the 100G series remote
gas module.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 39
Proprietary and Confidential