User's Manual
Rotary Meter Installation
4. Connect the meter cable to the 100G series remote gas module using 3M gel-cap connectors. Follow the
wire connection table and wiring diagrams below. See Installation Prerequisites on page 7 for appropriate
3M crimping tools.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel.
Gel flowing from the connector provides environmental protection for the connection.
American RPM Meter to the 100G series remote gas module Wire Connections
American RPM Meter wire ERT module wire
Black Blue
White White
Red Red
5. Insert the meter cable through the slot on the ERT module backplate. Install a cable tie to the meter cable
wire below the meter cable insulation to provide strain relief.
6. Tuck the connectors and cable tie into the ERT module housing. Place backplate on the assembly and
tighten the four backplate screws using a size T-10 Torx screwdriver.
Important Verify the cable tie and gel connectors are inside the module housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 37