6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female connector
inside the meter's tower. The connectors will slide together and latch.
7. Carefully push the connectors and wires into the meter tower housing.
8. Lubricate the O-ring with O-ring lubricant and install the O-ring on the adapter plate. Insert the adapter
plate into the tower and tighten the two 5 mm screws.
To connect the manufacturer cable to the ERT module
Note Connection to an Elster American Meter requires a cable interface compatible to an Elster
American Meter RPM rotary meter.
1. Trim the ERT module wires to 3.5 inches.
2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer)
approximately 1-1/2-inches from the end.
Caution Do not cut through the individual wire insulation.
3. Separate the meter cable's black, white, and red wires for connection to the 100G series remote gas
module. Cut off the unused wires even with the outer covering (insulation).
Caution Do not strip the individual wires.