Rotary Meter Installation
Programming the Remote ERT Module for GE Dresser Rotary
Meters
To program 100G series remote gas modules for use with GE Dresser rotary meters, use the meter drive rates
from the drive rate table in this section.
B3, LMMA & S3A CTR/TC Meter Drive Rates for Remote ERT Module
Programming
Caution Do not use these meter drive rates to program residential direct-drive or commercial direct-
drive modules. Use the information in the following tables to program ERT modules connected to GE
Dresser rotary meters.
B3, LMMA, S3A CTR/TC Meter Drive Rates
B3 CTR Meter Size
B3 CTR Meter Pulse Rate
8C 10
11C 10
15C 10
2M 10
3M 10
5M 10
7M 10
11M 10
16M 100
23M 100
38M 100
56M 100
Meters built 1/99 and beyond
Meters built prior to 1/99
B3 TC Meter Size
B3 TC Meter Pulse Rate
B3 TC Meter Size
B3 TC Meter Pulse Rate
8C 10 8C 50
11C 10 11C 50
15C 10 15C 50
2M 10 2M 50
3M 10 3M 50
5M 10 5M 50
7M 10 7M 50
11M 10 11M 50
16M 100 16M 500
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 30