4. Align the ERT module mounting holes with the ES3 or ETC bracket mounting holes. Use a T15 Torx
screwdriver to insert and tighten the mounting screws. Tighten the screws in an alternating pattern.
To confirm the correct ERT module mounting
Important Regardless of the meter orientation (side or top inlet), the 100G ERT module must always be
mounted in a vertical position with the arrow on the front label and the meter mounting bracket arrow
pointing up. Vertical positioning ensures the tilt/tamper switch in the module is in the correct position.
• The 100G ERT module is in the correct vertical mounting position when the arrow on the front label is
pointed upward.
Configuring Index Settings Using the GE Dresser MeterWare
Software
GE Dresser MeterWare software is used to configure the ERT module's index settings.
Important This information is subject to change without notice. Refer to the GE
Dresser MeterWare product documentation to verify the most current information
about programming and configuring the corrector for use with the 100G series remote
ERT module.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 28