User's Manual

Rotary Meter Installation
1. Splice the meter pulse output wires to the ERT module wires using gel cap connectors. Follow the wire
connections in the D800/D1000 to 100G ERT module wire connections table.
Pulse Outputs
D800/D1000 wire
Pulse output
1 only
Pulse output
2 only
Pulse output 2 with
fault (pulse out 3)
Pulse output 2 with fault
(pulse out 3)
Pulse output 1+
Brown White and Blue White
Pulse output 1-
Green Red Red
Pulse output 2+
White White and blue White
Pulse output 2-
Black Red Red
Pulse output 3+
(Fault)
Red White White
Pulse output 3-
(Fault)
Blue Blue Blue
Pulse Output 1 Only
Pulse Output 1 and Fault
Note See GE Dresser documentation for detailed information about pulse outputs 1 and 2. See the 100G
Series Remote ERT Module Meter Compatibility List on page 4 for pulse requirements and compatibilities.
2. After the wiring connections are completed, install the cable tie approximately 1/8" from the end of the
cable insulation as shown.
3. Position the portion of the cable with the cable tie (strain relief) into the slot on the ERT module's back
plate.
4. Carefully fold the ERT module wires into the ERT module housing. Be careful not to pinch the wires or
gel connections between the housing and the back plate.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 24
Proprietary and Confidential