User's Manual
Rotary Meter Installation
4. Rotate one bracket. Route the meter cable through the holes located at the bend of the mounting brackets.
5. Attach the brackets to the meter using the previously removed screws.
To connect the 100G ERT module to the meter
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow (3). If the silicone gel flows out of the crimped connector, avoid touching the
gel. Gel flowing from the connector provides environmental protection for the connection.
Note Connecting the D800 or D1000 to the 100G remote module requires 3M gel cap connectors. Itron
supplies the two-wire gel cap connectors. Users who want to complete three-wire connections must
supply the 3M UR2 connectors.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 23