4. Tuck the three gel connectors and cable tie inside the module housing, as shown in the following
placement schematic illustration.
5. Install the 100G series remote gas module backplate using the four screws previously removed from the
module and a Torx T-10 screwdriver.
Important Verify the cable tie and gel connectors are inside the module housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9 to 12 inch-pounds.
6. Install the module on the wall or a pipe using the Pipe Installation Kit (Itron part number CFG-0005-003).
For mounting instructions, see Mounting the 100G Series Gas ERT Module.
Connecting and Installing the GE Dresser D800/D1000 Meter
Meter manufacturers may provide ERT mounting kits and installation procedures. If GE Dresser's 100G series
to GE Dresser D800/D1000 meter installation procedure is not available, follow this procedure.
Installing the ERT module to the meter requires the following customer-supplied materials.
Requirement
Description
D800 or D1000 GE Dresser meter
ERG-500X-503
ERT modules include a cable tie for strain relief and tamper seals.
100G remote ERT module
Phillips-head screwdriver
Torx screwdriver T-15
Screws (1) 8-32 x 1/2"
(2) 8-32 x 3/4"
Kep® nuts (3) 8-32"
3M UR2 3-wire gel connector
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 21