User's Manual

Rotary Meter Installation
2. Insert the lead wires from the module into new 3M gel connectors (Itron part number CON-0023-001)
together with the same colored lead wire from the meter cable (see the wiring table below) and crimp
using a 3M hand-held crimping tool.
Rotary Meter to Remote ERT Module Wire Table
Rotary meter wire Remote ERT module wire
Red Red
White White
Blue Blue
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel connectors. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel connector is fully crimped (collapsed) to allow time for the low
viscosity silicone-based gel to flow (3). If the silicone gel flows out of the crimped connector, avoid
touching the gel. Gel flowing from the connector provides environmental protection for the connection.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
3. After completing the wiring connections, install a cable tie to the meter cable just below the exposed
colored lead wires on the cable insulation. Remove the excess cable tie using a hand-held side-cutter
pliers. The cable tie performs as a cable strain relief to mitigate the risk of destructive tension on the lead
wires.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 20