User's Manual

Rotary Meter Installation
Required Installation Materials Available from Itron
The materials in the following table are required to install the remote ERT module.
Itron Part Number
ERG-500X-503
ERG-500X-503
Note this remote ERT module comes standard with 12-inch lead wires and may be
shipped directly to the meter manufacturer for a factory-installed cable (interface). The
interface cable must be purchased directly from the meter manufacturer.
Important You must purchase the interface cable directly from the meter manufacturer.
CFG-0005-003
Pipe Installation Kit
Connecting the 100G Series Gas ERT Module to the GE Dresser
Rotary Meter Cable
You may ship the Itron 100G series remote gas module directly to GE Dresser for a factory-installed cable. If
you connect the module to the meter using an existing cable purchased from GE Dresser, complete the
following cable installation procedure.
Caution The purchased cable must have a mating connector compatible to the meter receptacle.
GE Dresser cables may be wired in different configurations for specific applications. If necessary,
contact GE Dresser for wiring diagrams for your specific application.
To connect the module to the rotary meter cable
1. Remove the backplate (4 screws) from the module and expose the module lead wires. The backplate and
screws will be re-installed on the ERT module later in this procedure so store them (temporarily) in a safe,
secure place.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 19
Proprietary and Confidential