User's Manual
Mounting the 100G Series Gas ERT Module
2. Push up on the module until the adapter plate mounting lug (1) is as far as possible inside the module
mounting lug recess (2).
3. Align the ERT module backplate mounting holes with the pipe mount adapter plate holes. Install the two
one-inch ERT module mounting screws from the installation kit.
4. Tighten the module mounting screws evenly in an alternating fashion. Tighten to 9 - 12 inch-pounds of
pressure.
To install tamper seals and cable ties
1. Place the new tamper seals from the Pipe Installation Kit over the 100G series remote gas module
mounting screws.
2. Firmly push both tamper seals all the way into place with a 1/4-inch nut driver or similar blunt tool.
Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16-inch below the
top of the screw recess.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 14
Proprietary and Confidential