User's Manual

This chapter provides the instructions to mount the 100G series remote gas module on a pipe or other flat
vertical surface (wall).
Installation Options
Mount the remote ERT module using the pipe mount or wall mount (flat vertical surface) procedure.
Pipe Mount. Pipe mounting is used in conjunction with the Pipe Installation Kit (Itron part number CFG-
0005-003). The pipe mount option places the module on a pipe near the meter or instrument (not on a wall
surface). This option requires a meter manufacturer's cable to connect the module to the meter or
instrument.
Flat Vertical (Wall) Mount. Installation using the wall mount option places the module on a wall or
other vertical surface. A cable connects the module to the meter or instrument.
Mounting Screw Specifications
Application Itron Part
Number
Description
To mount adapter plates on
pipe brackets
575-9930-016
8-16 x 1/2-inch length, type 8 slotted pan-head tapping
screw, corrosion-resistant steel
To mount remote modules on
adapter plates
575-9930-032
8-16 x 1-inch type 8, slotted pan-head tapping screw,
corrosion-resistant steel
To mount remote modules on
sheet metal surfaces (to mount
modules to wood surfaces, a
comparable wood screw is
required)
SCR-0009-001
10-16 x 1 1/2-inch type AB thread for sheet metal, Phillips
pan-head tapping screw, corrosion-resistant steel
C HAPTER 2
M
ounting the 100G Series Gas ERT Module
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 9
Proprietary and Confidential