User's Manual
About the 100G Series Gas ERT Module
Romet
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
RM Series
STD CTR
600—56000
TC 2000—23000
Meter must have factory-installed
pulser with connector output.
Purchase cable interface from
manufacturer.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
RM Series
Electronically
compensated
meter ECM2
600—56000
Meter must have connector pin
with factory-installed pulse output.
Purchase correct cable interface
from Romet. ECM2 must be
configured for 750ms "off-time"
between pulses. The ECM2 must
have firmware version J or later.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
AdEM
®
Series
Correctors
including AdEM
®
-
S, AdEM
®
-T, and
AdEM
®
-PTZ
Must be configured for 750ms "off
time" between pulses
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5006-503
ERG-5007-503
Sensus (Invensys/Equimeter/Rockwell/EMCO)
Meter Model
Meter Notes
100G Module Type
Iron Part Number
Gas Module Notes
Sonix Pulse
Output
12, 16, 25, 57
(Metric)
600, 880, 2000
(Cubic foot)
Sonix meters are pulse output
registers which are programmed
by Sensus software. Proper pulse
output options and display options
must be selected.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
Installation Prerequisites
The following tools are required to install, program, and check the remote 100G series remote gas module.
Some specific tools may be required dependent on meter or instrument type.
• Medium flat-blade screwdriver
• Small flat-blade screwdriver
• Medium Phillips screwdriver
• Hand pliers
• Side-cutting pliers
• 1/4-inch nut driver or similar blunt tool
• One-inch width putty knife
• Adjustable wrench
• 3M Scotchlock E-9Y crimping tool, 3M Scotchlock E-9C cartridge tool, or similar crimping tool
• All-weather electrical tape
• Mounting screws (for more information about mounting screws, see Mounting Screw Specifications on
page 9)
• Size T-15 Torx screwdriver
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 7
Proprietary and Confidential