User's Manual
About the 100G Series Gas ERT Module
Honeywell Mercury Instruments
Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes
Electronic TC
index:
TCI
Temperature Compensating Index.
TCI must have a Form A board,
Form C is NOT supported. Item
#56 Pulse Scaling Factor must be
2.0. Item #96 must be 7, 6, 5, or 4
digits (1, 2, 3, or 4 blanks). Item #
1014 set to the preset "Itron 100G"
selection in the drop-down menu.
Compatible TCI firmware versions
are 1.06, 1.07, and 1.10.
100G Datalogging Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
100G DLT Datalogging Remote
ERG-5002-502
ERG-5002-503
ERG-5003-502
ERG-5003-503
ERG-5006-502
ERG-5006-503
ERG-5007-502
ERG-5007-503
Itron (Actaris, Schlumberger, Sprague)
Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes
1A Flat-face meter where meter body
and 1A adapter plate have
interference fit issue causing direct
mount solution to be non-
compatible.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
305 #2 flat-face meter 100G Remote
100G Datalogging Remote
100G Datalogging RN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
400 #3 flat-face meter 100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
675, 1000 Front-mount index 100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
Requires a thicker gasket for
magnet hub to clear index
box.
1-hole gasket: FAB-0014-001
2-hole gasket: FAB-0014-002
3-hole gasket: FAB-0014-003
Dattus III fM1,
fM2, fM3
For all meter types, pulse width
must be set to .050 seconds. Meter
type 11M or smaller must have
pulse weight minimum of 10 cubic
feet or 1 cubic meter. Meter type
16M or greater must have pulse
weight minimum of 100 cubic feet
or 1 cubic meter.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-502
ERG-5002-502
ERG-5003-502
ERG-5006-502
ERG-5007-502
National (Lancaster)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
All Meters Where direct mount solution is not
compatible.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 6
Proprietary and Confidential