User's Manual

About the 100G Series Gas ERT Module
GE Oil & Gas/Dresser Meters
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
Integral Micro
Corrector IMC/W2
Electronic volume corrector for
Series A (LMMA) and Series B
rotary meters. Must be meter
firmware version 1.94 or earlier.
Pulse width must be set for
125ms. Pulse output must be at
100CF (CM) or higher.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-505
ERG-5002-505
ERG-5003-505
ERG-5006-505
ERG-5007-505
Integral Micro
Corrector MC2
Electronic volume corrector for
Series A (LMMA) and Series B
(rotary meters). Must be firmware
version 1.93 or earlier. Pulse
width must be set for 125 ms.
Pulse output must be at 100CF
(CM) or higher.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-505
ERG-5002-505
ERG-5003-505
ERG-5006-505
ERG-5007-505
Series 3 ES3
Electronic TC
Electronic TC with mechanical
backup. ES3 pulse width must be
set greater than 100ms. Firmware
version 1.71 or earlier.
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5000-505
ERG-5002-503
ERG-5002-505
ERG-5003-503
ERG-5003-505
ERG-5006-503
ERG-5006-505
ERG-5007-503
ERG-5007-505
Both ERT modules are
compatible with this meter
model.
Electronic
Temperature
Compensator
(ETC)
Electronic TC with no mechanical
backup. ETC pulse width must be
set greater than 100 ms.
Firmware version 1.71 or earlier.
100G Datalogging FN Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
100G DLT Datalogging Remote
ERG-5003-503
ERG-5003-505
ERG-5006-503
ERG-5006-505
ERG-5007-503
ERG-5007-505
Both ERT modules are
compatible with this meter
model.
Honeywell Mercury Instruments
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
Electronic
Correctors:
EC-AT
Mini-P
Mini-AT
Mini-Max
Pressure and temperature
electronic volume instruments.
Instruments must have a Form A
board, Form C is NOT supported.
Item #56 Pulse Scaling Factor
must be 2.0. Item #96 Cor Vol
Display must be 7, 6, 5, or 4 digits
(1, 2, 3, or 4 blanks). Item #115
Output Pulse Code must be set at
1, 2, or 4. For 100G connection to
Mini-Max only, Item #115 must be
set at 1 or 2. Item 124 wake up
setting on Honeywell corrector
must be set to 1. Compatible
corrector firmware versions are
2.5020 and 2.73.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-502
ERG-5002-502
ERG-5003-502
ERG-5006-502
ERG-5007-502
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 5
Proprietary and Confidential