User's Manual
About the 100G Series Gas ERT Module
100G Series Remote ERT Module Meter Compatibility List
The following table lists meter types compatible with the 100G series remote gas module. Due to continuous
research, product improvements and enhancements, Itron reserves the right to change product or system
specifications without notice.
Eagle Research
Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes
MPplus
Volume Corrector
Pulses with 70mS on and
500mS off timing.
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5003-502
ERG-5006-502
ERG-5007-502
XARTU-1 Pulses with 70mS and 100ms
on and 500mS off timing.
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5006-503
ERG-5007-503
Elster American (Canadian)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
10 Metric (10B) Originally manufactured by Metric
Metal Works
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
Rotary RPM Series
TC, STD CTR
(pulse output
connection)
Must have factory-installed pulser
with connector output. Purchase
correct cable interface from
manufacturer.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
Galvanic
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
GasMicro
Electronic Volume
Corrector
Must select 2 pulses/second from
pulse output--output frequency
menu.
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5003-503
ERG-5006-503
ERG-5007-503
ERT module cut cable
requires customer-supplied
cable capable of terminating
the ERT module white and
blue wires at the meter
interface.
GE Oil & Gas/Dresser Meters
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
D800/D1000 Pulse width must be set greater
than 100 ms. Firmware version
must be 1.71 or earlier.
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5003-503
ERG-5006-503
ERG-5007-503
ERG-5003-505
ERG-5006-505
ERG-5007-505
ERG-500X-503 and -505
modules interface with this
meter
B3/LMMA Pulse
output
Rotary meters equipped with
WeigandWire solid state pulsers.
Meter must have factory-installed
pulser with connector output.
Purchase correct cable interface
from GE. Pulser must be version
17 or higher to be compatible.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 4
Proprietary and Confidential