User's Manual
DATTUS Meter Installation
3. Mounting the 100G series remote gas module. The 100G series remote gas module may be mounted on a
pipe, or flat surface (see Mounting the 100G Series Gas ERT Module on page 9).
4. Connecting the 100G series remote gas module to the DATTUS III meter (see Connecting the Remote
ERT Module to the DATTUS Meter on page 90).
5. Programming the 100G series remote gas module (see Programming the DATTUS Meter on page 89).
Installing the Remote ERT Module to Itron DATTUS Meters
DATTUS meters provide an electronic pulse output compatible with the 100G series remote gas module. The
DATTUS meter may be wired to the ERT module using the pulse output cable or the module can be directly
mounted to the meter.
When ordering, customers can have the 100G series remote gas modules drop shipped to Itron's Owenton,
Kentucky meter factory to have a factory-installed connector attached to the module's bare leads. The
connector directly fits the pulse output on the DATTUS meter.
Connecting the Remote ERT Module to a DATTUS meter
The DATTUS fM2 and fM3 meters have two configurable outputs usable as pulse outputs to the 100G series
remote gas module. Connecting the module following the information in this section requires a pulse output
cable, installed at the Owenton, Kentucky Itron location. Pulse output cables are available in 10-foot and 20-
foot lengths. Factory-installed cables have a Binder connector on one end and three bare wires on the opposite
end.
DATTUS Meter Wiring Accessories (available from Itron, Owenton, Kentucky)
Accessory Itron Part Number
Pulse output cable - 10 ft. 442461-009
Pulse output cable - 20 ft. 442461-010
Pulse output cable
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 90