User's Manual

This section provides the instructions to install the 100G series remote gas module with Itron DATTUS
meters.
DATTUS III fM1 DATTUS III fM2 DATTUS III 3
Installation Prerequisites
100G series remote gas module installation to a DATTUS III meter requires the following materials:
100G series remote gas module compatible with the DATTUS III meter (see the 100G Series Remote
ERT Module Meter Compatibility List on page 4).
Itron DATTUS III meter compatible with the 100G series remote gas module.
Tools and devices to complete installation and programming (see Installation Prerequisites on page 7).
Programming the DATTUS Meter Parameters
Program the DATTUS meter with the correct pulse width and weight. For all DATTUS III type meters, the
pulse width must be set to .050 seconds.
DATTUS Meter Pulse Weight Settings
Meter type Pulse weight in cubic feet (CF)
or cubic meter (CM)
11M or smaller 10 (CF) or 1 CM
16M or greater 100 CF or 1 CM
Installation Overview
Installing the 100G series remote gas module to a DATTUS III meter involves five tasks:
1. Programming the meter (see Programming the DATTUS Meter on page 89 or the Itron DATTUS-Link
Programming Guide for more information).
2. Installing any necessary Itron retrofit parts. Customers can request Binder connectors be installed by Itron
prior to shipment.
C HAPTER 6
D
ATTUS Meter Installation
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 89