User's Manual

Sensus Sonix Meter Installation
Direct Mounting the Remote ERT Module to the Sonix Meter
The Sensus factory can direct mount the 100G series remote gas module to Sensus Sonix Meters (contact
Sensus North American Gas Customer Service for mounting specifications and ordering information). This
section includes the instructions for customers to mount the 100G series remote gas module on the Sonix
meter using the mounting materials available from Sensus Metering Systems.
A Top anchor screw positions
B Bottom anchor position for the module U-shaped mount
Sensus Sonix Direct Mount Brackets* and Mounting Hardware
Sensus Part Number
Description
60025-063-00000 1 1/2" FTP, 45Lt, #3 Spg, 60Lt, #4 Spg
60025-063-01000 2" - 11BS, 2" FTP
60025-063-02000 30Lt, #1A Spg, 1 1/4" NPT, #2 Spg, 20Lt
903376 #8-32 x 3/4" SS Fillister-head screws (2 required)
011-14-286-00 Rubber mounting washer
Stabilizes bracket/100G series remote gas module assembly
*Order the correct bracket for your installation requirements from Sensus North American Gas Customer
Service. Brackets and mounting hardware are ordered separately.
To direct-mount the 100G series remote gas module on the Sonix meter
1. Place the ERT mounting bracket over the inlet or outlet pipe fitting on the Sonix meter. (The default
position is over the inlet connection. The inlet connection is the left side connection looking at the meter
front.)
2. Remove the four ERT backplate screws and turn the backplate so the ERT mounting screw holes are to
the top of the ERT module (the arrow on the ERT module label must point up). Secure with the four ERT
backplate screws previously removed.
3. Slide the mounting lug (now on the bottom of the ERT module) over the bottom anchor. Insert the two top
ERT mounting screws and tighten in an alternating fashion.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 95
Proprietary and Confidential