Electronic Volume Corrector and Instrument Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 44
Proprietary and Confidential
To connect the 100G Datalogging FN remote ERT module to the IMC/W2 or MC2 cable
1. Remove the backplate (4 screws) from the 100G Datalogging FN remote ERT module and expose the
module lead wires. The backplate and screws will be re-installed on the module later in this procedure so
store them (temporarily) in a safe, secure place.
2. Insert the lead wires from the 100G Datalogging FN remote ERT module into new 3M gel connectors
(Itron part number CON-0023-001) together with the same colored lead wire from the meter cable (see the
wiring table below) and crimp using a 3M hand-held crimping tool.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel.
Gel flowing from the connector provides environmental protection for the connection.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
IMC/W2 to Remote ERT Module Wire Table
IMC/W2 Wire
Remote Module wire
Red
Red
White
White
Blue
Blue