Electronic Volume Corrector and Instrument Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 42
Proprietary and Confidential
3. Place the strain relief fitting onto the field pulse cable.
4. If the field pulse cable is smaller than a 0.2-inch diameter, install the rubber tube supplied with the TCI
onto the cable so the strain relief will clamp onto the tube after it is re-installed.
5. Connect the individual external pulse cable conductors to the un-terminated wires following
Configuration for two endpoints connected to one TCI. Insert one un-terminated wire into an opening of a
gel-connector (six gel-connectors were included with the TCI). Insert the appropriate field cable wire into
the other gel-connector opening.
Configuration for two ERT modules connected to one TCI
Channel A
ERG-500x-503
TCI
White
Orange and brown
Red
Yellow
Blue
Blue (alarm)
Channel B
ERG-500x-503
TCI
White
White
Red
Green
Blue
White