User's Manual
Rotary Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 29
Proprietary and Confidential
To mount the 100G Datalogging FN remote ERT module on the Romet ECM2 meter
1. Remove the module screw from the back of the ECM2 meter and discard.
2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used as spacers as
shown.
3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw was removed.
Torque the mounting screw to 5-7 ft.lbs. to secure the plate to the Romet meter.
4. Mount the 100G Datalogging FN remote ERT module using the pre-drilled holes on the mounting plate
and the module mounting screws.
5. Place new tamper seals over the two screws. Press tamper seals into place using an 11/32-inch nut driver
or similar blunt tool.