User's Manual

Rotary Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 27
Proprietary and Confidential
Mounting the 100G Datalogging FN Remote Mount ERT Module
Select an appropriate mounting location on adjacent piping close to the meter. Using the pipe bracket,
mounting plate and band clamps from the Remote Mount Kit (Itron part number CFG-0005-003), secure the
100G Datalogging FN remote ERT module. Use the cable ties from the kit to secure any excess wire to the
piping (see Mounting the 100G Datalogging FN Remote ERT Module on a Pipe on page 7).
Installing the Remote ERT Module to the Romet Electronically
Compensated Meter (ECM2
®
)
The Romet ECM2
®
meter has three Form A outputs that can be configured at the factory to provide any
combination of the following three outputs:
Uncorrected volume (UNC VOL)
Corrected volume (COR VOL)
Alarm
The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items > SET UNC OUT
and Menu items > SET COR OUT. Since Setup Mode is fully configurable, the ECM2
®
module is
universally adaptable to all Romet TC meter bodies. Reference the Romet technical manual for specific details
on the ECM2
®
.