User's Manual
Rotary Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 26
Proprietary and Confidential
5. Insert the meter cable through the slot on the ERT module backplate. Install a cable tie to the meter cable
wire below the meter cable insulation to provide strain relief.
6. Tuck the connectors and cable tie into the ERT module housing. Place backplate on the assembly and
tighten the four backplate screws using a size T-10 Torx screwdriver.
Important Verify the cable tie and gel connectors are inside the module housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds.
To install the Datalogging FN remote ERT module cable
1. Insert the plug on the cable connected to the ERT module into the receptacle on the meter adapter plate.
2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify the
connection is hand-tight.