Rotary Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 25
Proprietary and Confidential
4. Connect the meter cable to the 100G Datalogging FN remote ERT module using 3M gel-cap connectors.
Follow the wire connection table and wiring diagrams below. See Installation Prerequisites on page 5 for
appropriate 3M crimping tools.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel.
Gel flowing from the connector provides environmental protection for the connection.
American RPM Meter to Datalogging FN remote ERT module Wire Connections
American RPM Meter wire
100G Datalogging FN remote mount ERT module wire
Red
Red
White
White
Black
Blue