User's Manual
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 11
Proprietary and Confidential
To mount the 100G Datalogging FN remote ERT module on the adapter plate
1. Take the 100G Datalogging FN remote ERT module and the two one-inch mounting screws from the
Remote Mount Installation kit. Place the back of the remote endpoint against the face of the adapter plate.
The adapter plate mounting lug (1) must be positioned just above the endpoint mounting lug recess (2).
2. Push up on the 100G Datalogging FN remote ERT module until the adapter plate mounting lug (1) is as
far as possible inside the module mounting lug recess (2).
3. Install the two one-inch ERT module mounting screws from the installation kit.
4. Tighten the module mounting screws evenly in an alternating fashion. Itron recommends 9 to 12 inch-
pounds of pressure.