User's Manual
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 10
Proprietary and Confidential
To mount the adapter plate on the pipe bracket
Caution Vertical mounting position is important to maximize RF performance. Mount the 100G
Datalogging FN remote ERT module with the module's label arrow pointing up. The module's arrow
must never point to either side or upside down. The module's tilt tamper functionality is designed to
operate with the module installed vertically.
1. Place the adapter plate on the pipe bracket with the mounting lug at the top or bottom. The adapter plate
screw bosses fit into the pipe bracket recess.
2. Ensure the adapter plate is positioned as shown below with the mounting lug (1) at the top or bottom. To
install the adapter plate on a vertical pipe, use the two shortest (1/2-inch) adapter plate mounting screws
from the Remote Mount Installation Kit. Place the mounting screws (2) in the holes shown below.
Upright module mounting
3. Tighten both screws securely in an alternating fashion. Itron recommends 9 to 12-inch-pounds torque.