User's Manual

Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 8
Proprietary and Confidential
Mounting the Remote ERT Module on a Pipe
The following items are required to mount the 100G Datalogging FN remote ERT module on a pipe or
vertical flat surface (wall):
Itron Part
Number
Description
ERG-5003-501
ERG-5003-502
ERG-5003-503
ERG-5003-505
100G Datalogging FN Remote ERT Module
(ERG-5003-501 shown)
CFG-0005-003
Remote Mount Installation Kit
Kit includes:
2 band clamps
2 tamper seals
pipe bracket
cable ties
adapter plate
Screws:
(2) 1/2-inch - to attach the adapter plate to pipe bracket
(2) 1-inch - to attach the ERT module to the adapter plate
(3) 1 1/2-inch - to attach the ERT module to a vertical surface
(wall)
Warning Install the 100G Datalogging FN remote ERT module in an upright position. Any
position other than upright can negatively affect radio performance and potentially reduce
battery life.
To mount the pipe bracket on a vertical pipe
Caution Vertical mounting position is important to maximize RF performance. Mount the 100G
Datalogging FN remote ERT module with the module's label arrow pointing up. The module's
arrow must never point to either side or upside down. The module's tilt tamper functionality is
designed to operate with the module installed vertically.
1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number
CFG-0005-003).