User's Manual

100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 4
Proprietary and Confidential
Meter
Model
Description
Class
Comments
ERT Module Type
ERT Module
Part Number
Romet
RM Series
ECM2
Electronically
compensated meter
Commercial
Meter must have connector pin
with factory-installed pulse
output. Purchase endpoint from
Itron and correct cable interface
from Romet. ECM2 must be
configured for 750ms "off-
time" between pulses. The
ECM2 must have firmware
version J or later.
100G Datalogging Remote
(12" lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5002-503
ERG-5003-503
Dresser ROOTS
®
B3/LMMA
Dresser ROOTS
®
rotary meters equipped
with WeigandWire
solid state pulsers
Commercial
Meter must have factory-
installed pulser with connector
output. Purchase endpoint from
Itron and correct cable interface
from Dresser. Dresser pulser
must be version 17 or higher to
be compatible.
100G Remote (12" lead
wires)
100G Datalogging Remote
(12" lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5000-503
ERG-5002-503
ERG-5003-503
Dresser ROOTS
®
IMC/W2
MC2
Dresser ROOTS
®
Micro Correctors
Commercial
Endpoint compatibile with
IMC/W2 firmware version
1.93 or earlier. Pulse width
must be set for 125ms. Pulse
output must be at 100CF(CM)
or higher.
100G Datalogging Remote
(12 lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5002-505
ERG-5003-505
Itron/Actaris
DATTUS fM2/fM3
Commercial
For all meter types, pulse width
must be set to .050 seconds.
Meter type 11M or smaller
must have pulse weight
minimum of 10 cubic feet or 1
cubic meter. Meter type 16M
or greater must have pulse
weight minimum of 100 cubic
feet or 1 cubic meter.
100G Datalogging Remote
(5' cable)
100G Datalogging FN
Remote (5' cable)
ERG-5002-502
ERG-5003-502
Mercury Instruments
EC-AT
Mini-P
Mini-AT
Mini-Max
Pressure and
temperature electronic
volume correctors
Commercial
Correctors must have a Form A
board; Form C is NOT
supported. Item #056 Pulse
Scaling Factor must be set to
2.0. Item #096 Cor Vol Display
must be set at 1, 2, 3, or 4
blanks. endpoint does NOT
support a setting of 0 blanks.
Item #115 Output Pulse Code
must be set at 1, 2, 3, or 4.
endpoint does NOT support an
Output Pulse Code of 0.
100G Remote (5'cable)
100G Datalogging Remote
(5' cable)
100G Datalogging FN
Remote (5' cable)
ERG-5000-502
ERG-5002-502
ERG-5003-502
Mercury Instruments
TCI
Temperature
Compensating Index
Commercial
Correctors must have a Form
A board, Form C is NOT
supported. Item #56 Pulse
Scaling Factor must be 2.0.
Item #96 must be 7, 6, 5, or 4
digits (1, 2, 3, & 4 blanks).
Endpoint does NOT support 8
digits (0 blanks). Item # 1014
set to the preset Itron
selection in the drop down
menu. Compatible firmware
versions on TCI are 1.06,
1.07, and 1.10.
100G Datalogging Remote
(5 cable)
100G Datalogging Remote
(12 lead wires)
100G Datalogging FN
Remote (5 cable)
100G Datalogging FN
Remote (12" lead wires)
5: ERG-5002-502
12:ERG-5002-503
ERG-5003-502
ERG-5003-503