User's Manual
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 52
Proprietary and Confidential
This chapter provides the instructions to install Remote 100G Datalogging FN remote ERT modules (Itron
part number ERG-5003-501 with 2.5 foot cable and encoder) on the diaphragm gas meters where a direct
mount endpoint is not possible. Reference the Itron Gas Endpoint Meter Compatibility List (PUB-0117-002 or
the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3 for compatible
diaphragm meters.
Tools and Materials Supplied By You
Note 100G Datalogging FN remote ERT module installation to a diaphragm
meter may require additional tools and materials over those listed in Installation
Prerequisites on page 5.
The following user/installer-supplied tools and materials are required to install, program, and check the 100G
Datalogging FN remote ERT module:
Medium flat-blade screwdriver
Medium flat-blade, torque-measuring screwdriver
Medium Phillips screwdriver
Pliers
Side-cutting pliers or similar tool
1/4-inch nut driver or other blunt tool for seating ERT module tamper
Itron programming device to program and check 100G Datalogging FN remote ERT module installation
and operation:
FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro software version 5.3 or higher or
Field Deployment Manager (FDM) version 1.1 or higher
or
FC300 with SRead with Endpoint-Link or Endpoint Link Pro version 5.5 or higher Field Deployment
Manager (FDM) version 1.1 or higher
or
900 MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager (FDM)
version 1.1 or higher and a customer-supplied laptop
Note Reference the appropriate programming guide or specification sheet for correct software
version (see Related Documents on page 2).
1-inch putty knife or similar tool to remove old gasket material from the meter and index cover
Replacement temperature compensation (TEMP COMP) meter index stickers (if required)
C H A P T E R 5
Diaphragm Meter Installation