User's Manual

Electronic Volume Corrector and Instrument Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 49
Proprietary and Confidential
2. For the cable gland or conduit fitting:
a. Route the cable from the 100G Datalogging FN remote ERT module through the IMC\W2 cable
gland/conduit connector.
To receive uncorrected reads: connect the red wire to the terminal block 3 (TB3 telemetry output)
GND1 (ground) position (B). Connect the white and blue wires to the pulse output 1 position (A).
To receive corrected reads: connect the red wire to the GND 2/3 (ground) TB3 telemetry output position
(C). Connect the white and blue wires to the pulse output 2 position.
b. Tighten the cable gland fitting around the cable. Apply 15 inch-pounds torque.
Note 100G Datalogging FN remote ERT modules using the flying lead cable assembly (Dresser ROOTS
®
part number 055018-700) are factory wired to terminal block 3 (TB3) according to IMC\W2 pulse output
default configuration. Consult the customer specification for other wiring configurations.
To test the 100G Datalogging FN remote ERT module IMC\W2 installation
1. Connect the IMC\W2 to the PC using the serial cable.
2. Using the Dresser ROOTS
®
User Terminal (UT) communications software, connect to the IMC\W2.
3. Read the uncorrected or corrected count number on the 100G Datalogging FN remote ERT module with
the Itron endpoint reading device. Compare the IMC\W2 uncorrected or corrected amounts to the 100G
Datalogging FN remote ERT module
4. Input approximately 20 pulses to the 100G Datalogging FN remote ERT module. Verify the uncorrected
or corrected counts on the IMC\W2 and the Datalogging FN remote ERT module are the same.