Sensus Sonix Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 75
Proprietary and Confidential
Direct Mounting the Remote ERT Module to the Sonix Meter
The Sensus factory can direct mount the 100G Datalogging FN remote ERT module to Sensus Sonix Meters
(contact Sensus North American Gas Customer Service for mounting specifications and ordering
information). This section includes the instructions for customers to mount the 100G Datalogging FN remote
ERT module on the Sonix meter using the mounting materials available from Sensus Metering Systems.
A
Top anchor screw positions
B
Bottom anchor position for the endpoint U-shaped mount
Sensus Sonix Direct Mount Brackets* and Mounting Hardware
Sensus Part Number
Description
60025-063-00000
1 1/2" FTP, 45Lt, #3 Spg, 60Lt, #4 Spg
60025-063-01000
2" - 11BS, 2" FTP
60025-063-02000
30Lt, #1A Spg, 1 1/4" NPT, #2 Spg, 20Lt
903376
#8-32 x 3/4" SS Fillister-head screws (2 required)
011-14-286-00
Rubber mounting washer
Stabilizes bracket/100G Datalogging FN remote ERT module assembly
*Order the correct bracket for your installation requirements from Sensus North American Gas Customer
Service. Brackets and mounting hardware are ordered separately.
To direct-mount the 100G Datalogging FN remote ERT module on the Sonix meter
1. Place the endpoint mounting bracket over the inlet or outlet pipe fitting on the Sonix meter. (The default
position is over the inlet connection - left side connection looking at the meter front.)
2. Remove the four endpoint backplate screws and turn the backplate so the endpoint mounting screw holes
are to the top of the endpoint (the arrow on the endpoint label must point up). Secure with the four
endpoint backplate screws previously removed.
3. Slide the mounting lug (now on the bottom of the endpoint) over the bottom anchor. Insert the two top
endpoint mounting screws and tighten in an alternating fashion.