User's Manual
DATTUS Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 68
Proprietary and Confidential
Direct Mounting the Remote ERT Module to the DATTUS Meter
100G Datalogging FN remote ERT modules can be direct mounted to DATTUS fM2 and fM3 meters with the
DATTUS Direct Mount Kit (Itron part number 442491-001). You can rotate DATTUS meter registers to
accommodate vertical or horizontal meter. Customers may have Itron, Owenton, Kentucky complete the cover
modification and bracket attachment or may order the kit to retrofit the DATTUS meter. The external cover of
the DATTUS meter is modified with three holes to mount the endpoint bracket. The modification is
dependent on the orientation of the meter installation.
A Horizontally oriented meter endpoint mounting hole modifications.
B Vertically oriented meter endpoint mounting hole modifications.
Caution The 100G Datalogging FN remote ERT module must be mounted in an upright position
with the arrow on the label pointing upward.
After the meter cover and bracket are replaced on the meter, the 100G Datalogging FN remote ERT module is
connected to the pulse output of the DATTUS meter by the Binder Connector. The endpoint is seated into the
bracket to create a secure assembly.
Horizontal installation Vertical installation