User's Manual
Diaphragm Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 61
Proprietary and Confidential
To install the meter index covers over the ERT module encoder cable
1. Remove the gasket center and index cover hole plugs from the new gasket.
2. Insert the index/encoder assembly through the gasket center. Verify the gasket's adhesive-backed side is
facing the meter face.
3. Align the index wriggler with the meter's drive dog. Install the index on the meter using the index
mounting screws. Tighten one index screw two turns. Install and tighten the remaining index screw.
Tighten the first index mounting screw completely (alternating fashion).
4. Install a strain-relief cable tie about 1-1/4-inch from the encoder cable's stripped end. The cable tie must
be inside the index cover after the cover is installed on the meter.