User's Manual

Diaphragm Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 58
Proprietary and Confidential
8. Press the magnet hub down over the hub spacer as far as possible. The bottom of the hub spacer may
touch the index face. Turn the dial after magnet hub installation to verify the index dial functions with a
smooth, easy rotation.
9. If the tip of the dial needle sticks out past the edge of the magnet hub, cut off the end of the dial needle as
close as possible to the magnet hub with a sharp, side-cutting pliers.
10. Remove the acetone stick applicator from the Remote Encoder Installation Kit (Itron part number CFG-
0081-001).
11. Select a location on the index face next to the magnet hub. After encoder installation, the encoder cable
must not interfere with the index dials.
Note If a TEMP COMP sticker is attached to the index where the encoder cable will mount, remove it
before cleaning with the acetone stick. If the sticker (or replacement sticker) must be put back on the
register face, place it in a new location on the index face after the encoder is attached.
12. Tilt the acetone stick vertically with the wick end down. Squeeze the acetone stick on the black dot until
the packet inside the pen breaks. Continue to hold the acetone stick vertical until the acetone wicks into
the foam applicator end.