User's Manual

Diaphragm Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 54
Proprietary and Confidential
Installing the 100G Datalogging FN Remote ERT Module
The 100G Datalogging FN remote ERT module mounts on a pipe using the Remote Mount Installation Kit
(Itron part number CFG-0005-003) or a vertical flat (wall) surface. Always mount the 100G Datalogging FN
remote ERT module with the printed label right-side-up (arrow pointing up -1), and the encoder wires (2) and
tamper seals (3) at the bottom, as shown.
Caution Upright vertical positioning is very important because:
100G Datalogging FN remote ERT modules are designed with the antenna in a
vertical direction so the antenna is parallel to the reading device (which has a
vertical antenna). Matching antenna polarity can greatly affect RF performance
and enable easy endpoint reading.
100G Datalogging FN remote ERT modules are designed so the tilt tamper is
vertical. It is important to maintain vertical positioning in the field to enable tilt
tamper stability.
100G Datalogging FN remote ERT module batteries must be vertical (installed
with the positive terminal upward) or battery life is compromised.