User's Manual
Chapter 2 Elster American Meter Installation
18 100G Datalogging Installation Guide - Direct Mount
Attaching the 100G Datalogging Gas Endpoint Assembly to
the Elster American Meter
After 100G Datalogging Gas Endpoint programming is complete, attach the endpoint
assembly to the Elster American Meter.
Warning For 5B Meters only: If the 100G Datalogging Gas Endpoint
will be installed on a 5B-225 aluminum meter, cut 1/16" off each
endpoint wriggler post to prevent the wriggler from rubbing on the face
of the nut holding the meter drive dog in place.
To Attach the 100G Datalogging Gas Endpoint
1. Align the endpoint wriggler to connect with the drive post (or slot) of the meter.
For one-foot meters: Align the endpoint assembly wriggler perpendicular to the meter
drive post.
For two-foot meters: Align the endpoint assembly wriggler perpendicular to the meter
drive slot. The pin on the endpoint wriggler may be installed inside or outside the
meter drive slot. For easy assembly, Itron recommends installing the pin on the 100G
Datalogging Gas Endpoint wriggler outside the meter drive slot.