Chapter 7 Sensus/Rockwell Commercial Meter Installation
76 100G Datalogging Installation Guide - Direct Mount
Attaching the 100G Datalogging Commercial Endpoint to a
Sensus/Rockwell Commercial Diaphragm Meter
Warning Handle the 100G Datalogging Commercial Gas Endpoint carefully so
the metal passive radiator antenna is not damaged.
To Attach the 100G Datalogging Commercial Endpoint
1. Tilt the 100G Datalogging Commercial Gas Endpoint at an angle and turn the
wriggler until the drive notches line up with the meter wriggler's drive teeth.
2. Align the 100G Datalogging Commercial Gas Endpoint so the screw holes line up
with the meter's top screw holes. Carefully lower the endpoint on the meter so the
wriggler's bars line up with the meter drive dog. Itron recommends installation with
one bar inserted into the meter drive dog's u-shaped gear.
Warning The INLET label on the 100G Datalogging Commercial Gas Endpoint
must line up with the INLET label on the Sensus/Rockwell meter case.