User's Manual

Itron/Sprague Meter Installation
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 36
Proprietary and Confidential
To attach the 100G Datalogging gas endpoint assembly to a flat-faced Sprague meter
1. Verify the kit includes the materials listed in the Itron Adapter Plate Kit table.
Warning The Adapter Plate must fit flush against the meter face. Some older
Sprague meters are not compatible with the adapter plate. The following
examples illustrate the potential obstruction (problem) areas between the
adapter plate and meter. Failure to mount adapter plate flush on the front of a
meter could result in a binding condition and lead to poor registration or meter
failure.
2. Remove the drive dog from the flat-faced Sprague meter. Replace it with the extended drive dog included
in the kit. Hand-tighten to snug.
Warning The meter drive dog shaft is surrounded by a gasket. A gas leak
could result if the gasket is damaged. Do not use a tool to install or tighten the
new drive dog. Hand-tighten only.