TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 64
Proprietary and Confidential
3. Inlet lettering on the 100G Datalogging commercial gas endpoint must line up with Inlet lettering on the
meter. Slowly lower the endpoint on the Itron/Sprague/Actaris/Schlumberger commercial meter aligning
the drive dog and wriggler. The endpoint housing should rest on the top of the meter without gaps.
Warning Do not press down on the 100G Datalogging commercial gas
endpoint if a gap exists between the endpoint and the meter. A gap may be
caused by misalignment of the endpoint wriggler and meter wriggler's drive
teeth. Pushing down on the endpoint could damage the endpoint wriggler or
meter drive teeth. To eliminate a gap, remove the 100G Datalogging
commercial gas endpoint and repeat steps 2 and 3.
To attach the index/cover assembly on the meter
1. Place the Itron adapter plate on the 100G Datalogging commercial gas endpoint with the two small screw
holes in the adapter plate to the back of the meter.