User's Manual

Sensus/Rockwell Commercial Meter Installation
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 72
Proprietary and Confidential
To attach the 100G Datalogging commercial gas endpoint on the Sensus/Rockwell
commercial meter
1. Tilt the 100G Datalogging commercial gas endpoint at an angle and turn the wriggler until the drive
notches line up with the meter wriggler's drive teeth.
2. Align the 100G Datalogging commercial gas endpoint so the screw holes line up with the meter's top
screw holes. Carefully lower the endpoint on the meter so the wriggler's bars line up with the meter drive
dog. Itron recommends installation with one bar inserted into the meter drive dog's u-shaped gear.
Warning The INLET label on the 100G Datalogging commercial gas endpoint
must line up with the INLET label on the Sensus/Rockwell meter case.
3. Verify the bottom of the 100G Datalogging commercial gas endpoint and the top of the meter meet. The
endpoint housing should rest on top of the meter without gaps.
Warning Do not press down on the 100G Datalogging commercial gas
endpoint if a gap exists between the endpoint and the meter. A gap may be
caused by misalignment of the endpoint wriggler and meter wriggler's drive
teeth. Pushing down on the endpoint could damage the endpoint wriggler or
meter drive teeth. To eliminate a gap, slowly turn the 100G Datalogging
commercial gas endpoint's upper wriggler back and forth until the endpoint
aligns with the meter's drive teeth.