Attaching the 100G Datalogging Gas Endpoint Assembly to the
Sensus Meter
After 100G Datalogging gas endpoint programming is complete, attach the endpoint assembly to the Sensus
meter.
To attach the 100G Datalogging gas endpoint to the meter
1. Gently place the endpoint assembly against the front of the meter at angle.
2. Install and tighten endpoint-to-meter mounting screws in an alternating fashion.
Align the top right mounting screw-hole on the meter with the top right screw-hole on the endpoint.
Insert the top-right cover mounting screw and tighten the screw enough to hold it in place. Do not
completely tighten.
Rotate the endpoint assembly counterclockwise until the remaining three endpoint screw holes line up
with the holes in the meter. Use the original mounting screws if they were the correct size and not
corroded. If the original screws were discarded, use the correct replacement screws (see Installation
Prerequisites on page 7).