User's Manual

Elster American Meter Installation
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 13
Proprietary and Confidential
If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting screw holes,
perform steps 3 and 4, and skip steps 5 and 6.
3. Using the original index mounting screw or a replacement screw, if necessary, place one 8 - 32 3/16"
screw into the index's right-hand mounting screw hole.
4. Attach the screw to the endpoint housing's right-index mounting post just enough to hold the screw and
the right end of the index in place.
5. Screw one 8 - 32 x 3/16" screw into the right index mounting post one or two turns. Do not tighten the
screw.
6. Place the right index mounting screw slot under the screw head. Do not tighten the screw.
7. Slide the index drive post into the endpoint wriggler. Verify positive engagement.
Caution If the index wriggler has a drive slot, place the endpoint wriggler's drive post into
the index drive slot. Failure to mate the endpoint wriggler with the index drive post (or slot)
can cause binding and lead to poor registration or meter failure.