This chapter provides the instructions to install the 100G Datalogging gas endpoint on an Elster American
Meter.
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other
leftover materials. Do not leave materials on customer premises.
To remove the index from the meter
1. Remove the four index cover screws and the index cover from the Elster American meter. Alternate screw
removal following the numbered pattern in the photo.
2. Examine the mounting screws. If they are 5/8" long and not corroded, keep them to re-attach the 100G
Datalogging gas endpoint assembly. If the screws are not the correct length or if the screws are corroded,
discard.
Note You may use the removed index cover as a temporary storage container for
screws. Properly dispose all unused screws, old index covers, gaskets, tamper seals, and
other leftover materials. Do not leave materials on customer premises.