User's Manual

100G Datalogging Gas Endpoint
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 7
Proprietary and Confidential
Mfg.
Model
Description
Class
Comments
Endpoint Type
Endpoint Part
No.
EMCO
#2 ½
Commercial
100G
100G Datalogging
ERG-5000-008
ERG-5002-008
EMCO
#3
Commercial
100G
100G Datalogging
ERG-5000-008
ERG-5002-008
EMCO
#4
Commercial
100G
100G Datalogging
ERG-5000-008
ERG-5002-008
EMCO
#4 ½
Commercial
100G
100G Datalogging
ERG-5000-008
ERG-5002-008
EMCO
#5
Commercial
100G
100G Datalogging
ERG-5000-008
ERG-5002-008
Dresser ROOTS
Series B3
8C - 56M
8C - 16M
CTR
TC
(No pulser
No instrument drive)
Commercial
To attach an Elster
American endpoint, install
Dresser's Elster American
AMR adapter kit.
100G
100G Datalogging Dresser
adapter P/N 059599-000
ERG-5000-001
ERG-5002-001
Dresser ROOTS
Series A1
(LMMA)
1.5M - 5M
CTR
(No pulser
No instrument drive)
Commercial
To attach an Elster
American endpoint, install
Dresser's Elster American
AMR adapter kit.
100G
100G Datalogging
Dresser adapter P/N
058530-610
ERG-5000-001
ERG-5002-001
Dresser ROOTS
Series A1
(LMMA)
7M - 16M
CTR
(No pulser
No instrument drive)
Commercial
To attach an Elster
American endpoint, install
Dresser's Elster American
adapter kit.
100G
100G Datalogging Dresser
adapter P/N 058531-610
ERG-5000-001
ERG-5002-001
Dresser ROOTS
Series A1
(LMMA)
1.5M - 16M
TC
(No pulser
No instrument drive)
Commercial
To attach an Elster
American endpoint, install
Dresser's Elster American
AMR adapter kit.
100G
100G Datalogging
Dresser adapter P/N
058224-641
ERG-5000-001
ERG-5002-001
Dresser ROOTS
5C/8C15
Series Z compact meter
Commercial
To attach an Elster
American endpoint, install
Dresser's Elster American
adapter kit.
100G
100G Datalogging Dresser
adapter P/N 059847-000
ERG-5000-001
ERG-5002-001
Dresser ROOTS
B3/LMMA
Instrument drive
Commercial
Standard index drive and
no instrument.
100G
100G Datalogging
ERG-5000-007
ERG-5002-007
Installation Prerequisites
Prior to installation, verify you have the following items:
100G Datalogging gas endpoints designed for your specific brand of residential or commercial gas meters
(endpoints include new tamper seals).
A compatible meter (see the Meter Compatibility List on page 2).
A compatible index. Itron 100G Datalogging gas endpoints are compatible with standard dial and direct-
read (odometer) indexes. Exceptions are noted on the Meter Compatibility List on page 2.
Installation tools (provided by installer or customer)
Small and medium flat-blade or Phillips screwdrivers - to remove and tighten index and index-cover
screws.
Side-cutting plier/wire snips - to cut wire seals, if applicable.