User's Manual

Chapter 4 Actaris Meter Installation
40 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
5. Loosen the index mounting screws one-half turn.
6. Slide the index off its mounting screws and remove from the meter. Set the index
where it won't get damaged or dirty.
7. Remove the index mounting screws from the meter. Check the screws for length and
corrosion. If they are 1/4 inches long and not corroded, you can use them to attach the
index to the 100G ERT Module.
If the screws are not the correct length, or are corroded, dispose of them properly.
Replace them with the screws listed in
Replacement Screws on page 38.
8. Remove all traces of the old index gasket from the meter. The new 100G ERT Module
has its own gasket.
9. Dispose of the old gasket properly. Do not leave it on the customer premises.