User's Manual

Chapter 6 American/Actaris Commercial Meter Installation
62 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Materials Supplied by Itron
The following items are supplied by Itron:
100G ERT Module
New tamper seals
Four screws for securing the 100G ERT Module assembly to the meter. These screws
may have holes drilled into the heads to accept wire tamper seals.
Two internal-tooth star washers for the mounting screws when using metal index
plates.
Two cork washers and two flat washers for the mounting screws when using plastic
index covers.
Materials Supplied By You
You must supply the following items to install, initialize, and check the 100G ERT Module
on the meter.
Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
index and index-cover screws.
Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
necessary.
11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
over screw holes.
FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program
and check ERT assembly.
Replacement Screws
Use 12 - 24 x 1/2-inch slotted, Fillister head machine screws (drilled to accept wire seals)
for replacement screws to mount the index cover.
Pre-installation Preparations
Before installing the 100G ERT Module on a meter, verify:
All Itron 100G ERT Module gas modules are compatible with your brand of gas
meter.
See the Meter Compatibility List for compatible meter model numbers for the
100G ERT Module