Installing 100G ERT Module on Actaris
Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 75
8. Gently place the index assembly onto the adapter plate and install the two index
mounting screws.
9. Place the index cover over the index assembly. The transparent section of the cover
must be on the same side as the index dials so the meter dials can be easily read.
10. Align the four holes in the index cover with the holes located in each corner of the
adapter plate and install the long cover screws.
11. Turn each screw 1/4 to 1/2 turn after it contacts the cover.
12. Place the tamper seals into the front right and back left screw holes of the index cover.
13. Install tamper seals over the screws and press them into place with an 11/32 nut
driver, or some other blunt tool. The tamper seals should not protrude above the index
cover screw holes.
14. Complete necessary paperwork and properly dispose excess installation and scrap
materials.