User's Manual

Chapter 7 Sensus Commercial Meter Installation
84 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
5. Place the index on top of the 100G ERT Module and line up the mounting holes.
Install the ERT module mounting screws (Itron part number SCR-0062-003).
6. Turn each screw 1/4 to 1/2 turn after it contacts the mounting plate. If you are using a
torque wrench, tighten to 72 inch-pounds.
7. Install the index cover:
For plastic covers with a flat surface for screw holes: use screws (Itron part
number SCR-0062-002), flat washers (Itron part number WSH-0020-005), and
cork washers (Itron part number WSH-0032-001).
NOTE Some plastic covers have a raised boss area for screw placement. In
this case, use screws and red tamper seals. Press the tamper seals into place
with an 11/32 nut driver or other blunt tool.